CORTEXA
← Browse
arxivphysics.med-phcs.AI2026-07-22

PRIME-SVR: Physics-infoRmed Implicit Multi-Echo Slice-to-Volume Reconstruction for Fetal T2 mapping

Busra Bulut, Maik Dannecker, Thomas Sanchez, Sara Neves Silva, Steven Jia, Jean-Baptiste Ledoux, Leo Pomar, Joanna Sichitiu, Yvan Gomez, Meriam Koob, Vincent Dunet, Maria Deprez, Guillaume Auzias, Francois Rousseau, Jana Hutter, Daniel Rueckert, Meritxell Bach Cuadra

Slice-to-volume reconstruction (SVR) is the standard method for obtaining high-resolution (HR) 3D fetal brain volumes from motion-corrupted 2D MRI slice stacks acquired in multiple orientations. Existing SVR methods are optimized and validated only for clinical-range echo times (TEs), limiting their use at non-clinical TEs and making them incompatible with quantitative T2 mapping, a protocol- and center-independent biomarker of fetal brain maturation requiring HR reconstructions across multiple TEs. We present PRIME-SVR, the first implicit neural representation (INR) framework for joint HR reconstruction from multi-echo MRI. A single fully connected network models a continuous function from spatial coordinates to signal intensities across TEs, while a second network estimates slice-specific acquisition degradations. Cross-TE coherence is enforced via a Bloch equation-derived regularization penalizing deviations from expected T2 decay, with adaptive weighting that strengthens coupling for degraded stacks. The method is fully self-supervised. We validate PRIME-SVR on 39 in vivo fetal acquisitions (13 subjects x 3 TEs) from two centers, two vendors, and two field strengths (1.5 T and 0.55 T). Compared to state-of-the-art SVR, PRIME-SVR improves reconstruction sharpness by 47%, anatomical accuracy by 30%, and cross-TE structural consistency by 14%. It enables reconstruction at late TEs previously inaccessible to SVR, yielding the first 0.8 mm isotropic T2 maps at 0.55 T and the first T2 maps derived from INR-based SVR. PRIME-SVR also accelerates quantitative imaging by reducing the data needed for multi-TE reconstruction, cutting acquisition from 15 to 10 minutes while keeping T2 accuracy within 1.7% in white and deep gray matter, or to 5 minutes with a mean T2 error of 2.3% for high-quality acquisitions.

View free PDFSource page

Related papers

arxivcs.LGcs.AIphysics.med-ph2026-07-07

Self-Supervised Implicit CEST Reconstruction via Physics-Informed Lorentz Encoding

Dexuan Li, Yupeng Wu, Chenglong Wang, Hanlin Liu, Hui Zhen, Jianqi Li, et al.

Multi-Pool Chemical Exchange Saturation Transfer (CEST) MRI provides valuable metabolic information but is clinically limited by long acquisition times. Although sparse sampling reduces scanning time, reconstructing high-resolution Z-spectra from limited data remains an ill-posed…

View free PDFSource page
arxivphysics.med-phcs.AIcs.LG2026-06-29

Physically-Constrained Harmonic Separation for Robust Heart and Respiratory Rate Estimation from Wrist Photoplethysmography

Nouhaila Fraihi, Ouassim Karrakchou, Mounir Ghogho

Wrist-worn photoplethysmography (PPG) enables continuous monitoring of cardiopulmonary physiology, but reliable heart rate (HR) and respiratory rate (RR) estimation in free-living conditions remains challenging due to non-stationary motion artifacts that spectrally overlap with p…

View free PDFSource page
arxivcs.HCcs.AIcs.ETphysics.med-phq-bio.NC2026-07-22

FMRP-LEAN: A HIPAA-Compliant AI-Augmented LIMS Architecture for End-to-End Clinical Assay Workflow Optimization

Eva McCord, Ernest Pedapati, Zag ElSayed

Clinical biomarker workflows in translational research settings often rely on spreadsheet-driven tracking, manual quality control (QC) reconciliation, and loosely integrated systems, resulting in limited state visibility, delayed reporting, and increased operational risk. These c…

View free PDFSource page
arxivphysics.med-phcs.AIcs.CVeess.IVeess.SP2026-07-03

Harmonic-Aware Transformer for Real-Time Catheter Localization in Interventional Procedures of Magnetic Particle Imaging

Abuobaida M. Khair, Wenjing Jiang, Xiaoli Yang, Moritz Wildgruber, Xiaopeng Ma

Magnetic particle imaging (MPI) enables real-time, radiation-free tracking of magnetic nanoparticle-coated instruments, making it highly suitable for interventional procedures. This study proposes a harmonic-aware transformer framework that directly predicts catheter tip position…

View free PDFSource page
arxivcs.NEcs.AI2026-07-17

Evolutionary Algorithm-Guided LLMs for Physics-Informed Neural Network Design

Xu Yang, Mingyang Yu, Jing Xu, Keqian Li

Physics-informed neural networks (PINNs) are unusually sensitive to interacting choices of architecture, activation, loss weighting, collocation, optimization, and constraint enforcement. Large language models (LLMs) can propose these choices, but independent recommendations do n…

View free PDFSource page
arxivcs.LGcs.AI2026-07-10

HypNO: A Graph-Based Neural Operator with Physics-Informed Message Passing for Hyperbolic Conservation Laws

Dimitrije Ždrale, Cassie An Jeng, Katie Wang, Sonia Vanier, Alexandre Bayen, Hossein Nick Zinat Matin

We introduce HypNO, a graph-based neural operator for scalar hyperbolic conservation laws. HypNO operates directly on a space-time graph of finite-volume cells and uses adjacency-factored, physics-informed message passing to respect upwinding and entropy admissibility near shocks…

View free PDFSource page