CORTEXA
← Browse
crossrefBioengineering2025-09-02Cited by 6

Machine and Deep Learning on Radiomic Features from Contrast-Enhanced Mammography and Dynamic Contrast-Enhanced Magnetic Resonance Imaging for Breast Cancer Characterization

Roberta Fusco, Vincenza Granata, Teresa Petrosino, Paolo Vallone, Maria Assunta Daniela Iasevoli, Mauro Mattace Raso, Sergio Venanzio Setola, Davide Pupo, Gerardo Ferrara, Annarita Fanizzi, Raffaella Massafra, Miria Lafranceschina, Daniele La Forgia, Laura Greco, Francesca Romana Ferranti, Valeria De Soccio, Antonello Vidiri, Francesca Botta, Valeria Dominelli, Enrico Cassano, Charlotte Marguerite Lucille Trombadori, Paolo Belli, Giovanna Trecate, Chiara Tenconi, Maria Carmen De Santis, Luca Boldrini, Antonella Petrillo

Objective: The aim of this study was to evaluate the accuracy of machine and deep learning approaches on radiomics features obtained by Dynamic Contrast Enhanced Magnetic Resonance Imaging (DCE-MRI) and contrast enhanced mammography (CEM) in the characterization of breast cancer and in the prediction of the tumor molecular profile. Methods: A total of 153 patients with malignant and benign lesions were analyzed and underwent MRI examinations. Considering the histological findings as the ground truth, three different types of findings were used in the analysis: (1) benign versus malignant lesions; (2) G1 + G2 vs. G3 classification; (3) the presence of human epidermal growth factor receptor 2 (HER2+ vs. HER2−). Radiomic features (n = 851) were extracted from manually segmented regions of interest using the PyRadiomics platform, following IBSI-compliant protocols. Highly correlated features were excluded, and the remaining features were standardized using z-score normalization. A feature selection process based on Elastic Net regularization (α = 0.5) was used to reduce dimensionality. Synthetic balancing of the training data was applied using the ROSE method to address class imbalance. Model performance was evaluated using repeated 10-fold cross-validation and AUC-based metrics. Results: Among the 153 patients enrolled in the studies, 113 were malignant lesions. Among the 113 malignant lesions, 32 had high grading (G3) and 66 had the HER2+ receptor. Radiomic features derived from both CEM and DCE-MRI showed strong discriminative performance for malignancy detection, with several features achieving AUCs above 0.80. Gradient Boosting Machine (GBM) achieved the highest accuracy (0.911) and AUC (0.907) in differentiating benign from malignant lesions. For tumor grading, the neural network model attained the best accuracy (0.848), while LASSO yielded the highest sensitivity (0.667) for detecting high-grade tumors. In predicting HER2+ status, the neural network also performed best (AUC = 0.669), with a sensitivity of 0.842. Conclusions: Radiomics-based machine learning models applied to multiparametric CEM and DCE-MRI images offer promising, non-invasive tools for breast cancer characterization. The models effectively distinguished benign from malignant lesions and showed potential in predicting histological grade and HER2 status. These results demonstrate that radiomic features extracted from CEM and DCE-MRI, when analyzed through machine and deep learning models, can support accurate breast cancer characterization. Such models may assist clinicians in early diagnosis, histological grading, and biomarker assessment, potentially enhancing personalized treatment planning and non-invasive decision-making in routine practice.

View free PDFSource page

Related papers

crossrefBioengineering2026-07-24

Beyond Size and Class Balance: Alpha as a New Dataset Quality Metric for Deep Learning

Josiah D. Couch, Rima Arnaout, Ramy Arnaout

In deep-learning-based image classification, achieving high performance requires diverse training sets. However, the current best practice—maximizing dataset size and class balance—does not guarantee dataset diversity. We hypothesized that, for a given model architecture, perform…

View free PDFSource page
openalexBioengineering2026-07-23

Quantitative Retinal Vascular Imaging Using Flood-Illuminated Adaptive Optics in Eyes with Lens Opacities

Yash Porwal, Kenaan Elbash, Marlon Diaz, Emily Butler, Saige Oechsli, Laurence Magder, et al.

Flood-illuminated adaptive optics (AO) imaging enables high-resolution quantification of retinal vascular morphology; however, its repeatability in older adults with lens opacities remains poorly characterized. In this prospective study, 40 subjects (66 eyes) underwent flood AO i…

View free PDFSource page
openalexBioengineering2026-07-23

Optimizing Transcutaneous Electrical Stimulation Based on Frequency-Dependent Tissue Modeling and Signal Analysis

Wenzhu Wu, Junquan Tang, Q Wang, Jun Yang

Transcutaneous electrical stimulation (TES) is limited by cutaneous discomfort caused by unavoidable activation of superficial sensory nerves during current delivery to deep targets. While psychophysical studies have empirically identified waveforms that reduce skin sensation, ex…

View free PDFSource page
openalexBioengineering2026-07-23

AI-Driven Robotic PCI: A Perception-to-Action Framework for Coronary Guidewire Control

Zijing Liu, Huanming Xu, Zhendong Liu, Jun Ma, J I N Liu, Pengfei Bi, et al.

Robotic percutaneous coronary intervention (PCI) remains predominantly teleoperated, while the most demanding part of the procedure, guidewire navigation through a moving coronary tree under fluoroscopy, still depends on the continuous human interpretation of vessel anatomy, card…

View free PDFSource page
crossrefBioengineering2026-04-17

Clinically Robust Deep Learning for Contrast-Enhanced Mammography: Multicenter Evaluation Across Convolutional Neural Network Architectures

Roberta Fusco, Vincenza Granata, Paolo Vallone, Teresa Petrosino, Maria Daniela Iasevoli, Roberta Galdiero, et al.

Background: This study investigates the impact of anatomically constrained preprocessing and deep learning architecture selection on benign versus malignant breast lesion classification in contrast-enhanced mammography (CEM), with the goal of improving robustness and clinical rel…

View free PDFSource page
crossrefBioengineering2026-04-15

Optimized Signal Acquisition and Advanced AI for Robust 1D EMG Classification: A Comparative Study of Machine Learning, Deep Learning, and Reinforcement Learning

Anagha Shinde, Virendra Shete, Ninad Mehendale

Electromyography (EMG) signals are critical for prosthetic control, rehabilitation, and human–machine interaction, yet their classification remains challenging due to noise, non-stationarity, and inter-subject variability. This study presents a comprehensive comparative analysis…

View free PDFSource page