Correction: Transcranial magnetic stimulation combined with functional near-infrared spectroscopy to elucidate the neurophysiological mechanisms of post-stroke hemiplegia: a systematic review
Yuzhe Zou, Xiangfeng Lai, Qian Liu, Hongmei Zhang, Hui Li, Wenhua Li, Dingwei He, Liqing Yao, Xue Yang
Correction on: Zou Y, Lai X, Liu Q, Zhang H, Li H, Li W, He D, Yao L and Yang X (2026) Transcranial magnetic stimulation combined with functional near-infrared spectroscopy to elucidate the neurophysiological mechanisms of post-stroke hemiplegia: a systematic review. Front. Neurol. 17:1824157. doi: 10.3389/fneur.2026.1824157 There was a mistake in figure 1 as published. The PRISMA flow diagram showed the number of included studies as 11. The correct number of included studies is 9. Two studies were excluded because they did not include TMS intervention. The corrected figure 1 appears below.There was a mistake in figure 2 as published. The study was erroneously labeled as "Tamashiro 2018". The correct label is "Tamashiro 2019". The corrected figure 2 appears below.The original version of this article has been updated.Reminder: Figures, tables, and images will be published under a Creative Commons CC-BY license and permission must be obtained for use of copyrighted material from other sources (including re-published/adapted/modified/partial figures and images from the internet). It is the responsibility of the authors to acquire the licenses, to follow any citation instructions requested by third-party rights holders, and cover any supplementary charges.Adding/removing text There were mistakes in the published text regarding study inclusion numbers, publication years, and task paradigm descriptions. A correction has been made to the section 3.1 Literature screening process: "...and finally, nine studies (37-45) met all the inclusion criteria and were included in this systematic review." A correction has been made to the section 3.2 Basic characteristics of included studies: "All studies were published between 2019 and 2025..." A correction has been made to the section 3.4 Characteristics of fNIRS assessment protocols: "block-design task states based on specific movements (e.g., finger opposition, grasping, etc., five studies). The laterality index (LI, three studies), functional connectivity (FC, five studies), and local efficiency, two studies." A correction has been made to the section 3.5.2 Clinical functional outcomes: "The remaining three studies did not report clinical outcomes." The original version of this article has been updated.for a reason not seen here, please contact the journal's editorial office.